EOD Isotope Identification Kit (EMEC100)


|
 |
|
|
The EOD kit provides two gamma/neutron detection systems that employ digital gamma spectrometers intended for rapidly identifying radioactive gamma/X-ray isotopes.
The kit comes complete with check sources, carrying holsters, setup software/cables and power adapters.
The identiFINDER-NGH (Gamma and Neutron) Complete System
The digital gamma spectrometer is intended for rapidly locating, accurately measuring, and quickly identifying radioactive gamma/X-ray isotopes. In addition, an integral PE moderated, 3He-neutron detector provides an indication of neutron intensity in cpm.
The gamma detector is a 31 x 38 mm (1.2” x 1.5”) NaI (Tl) detector with integral, exempt (15 nCi) 137Cs stabilization source, the useful measuring range is from background to 100 mrem/h. A vibration alarm feature is included, in addition to the audible and visual alarms, all of which can be preset for gamma dose & dose rate levels and neutron countrate. This unit is easily distinguished from the standard gamma only unit by its blue aluminum end cap.
Product Specifications:
Analyze • Detect • Measure • Control™
The EOD kit is supplied with a custom made black P-1600
Pelican case that contains the following:
• 2 x ID-NGH units
• 2 x web-gear compatible black carrying holsters with positive lock clasp
• 2 x wrist lanyards
• 2 x universal ac power supply units with "micro" USB connector
• 2 x micro USB to USB serial communication cables
• 2 sets of win TMCA software, technical manuals & calibration records
• 1 custom set of exempt radioactive check sources (RRS-8 EOD)
• 1 factory optimized spare detector assembly with set up sheet
User Selectable Nuclide Library
There are 74 reference spectra of radionuclides stored in 6 libraries (Nuclear, Industrial, Medical, Customs, OSI, and Security). All sub-libraries except OSI can be edited by adding or deleting specific nuclides from the list. Ten (10) reference spectra can be measured by the user and added to the predefined library spectra. Identification is done by a template-matching correlation procedure
Physical Dimensions
Weight: 2.75lbs (1250g) with 1.4" x 2" Nal and batteries
Temperature range: -20 to 55 °C (-4 to 122 °F)
Protection: water proof, dust tight
Protection class: IP 54
Drop test: 2' 8" on concrete
Dimensions: 9.8” x 3.7” x 3”
Spectrometry System Specifications
HV-Bias: 200 - 1275 V automatically set to suit individual detector
Shaping type: digital filter
INL, top 99%: <0.05%
DNL, top 99%: <0.1%
Spectrum length: 1024 channels
Pileup rejection: <100 nS, pulse pair res.
Throughput rate: >100,000 cps
Input rate: >350,000 cps
Spectrum memory: 100 spectra at 1024 channels
Real time presets: 1 s - 1,000,000 s
Live time presets: 1 s - 1,000,000 s
Dose/ Dose Measurement Specifications
Sensitivity: >10,000 cps/mrem for 1.4"x2" Nal (TI) detector
Dose-rate range: 1 ěrem/h - 100 rem/h
Dose range: 10 ěrem - 100 rem
Energy range: Nal: 15keV - 3.0 MeV; GM: 60 keV - 1.6 MeV
Alarm levels: Gamma: Four preset levels
Neutron: Separate neutron alarms for 3He model, with blue indicator lamp
|
 |
| |
|
|
| |
|
|
|
|
|
|
| |
|